GT-91128LIXCEL Wall Plug-in ICT/ITE Power Supply
GT-91128LIXCEL | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GT-91128LIXCEL, ICT/ITE Power Supply, Wall Plug-in, Li-Ion Battery Charger, , Input Rating: 100-240V~, 50-60 Hz, NEMA 1-15P, North America Blades, Class II 2 Conductors, Output Rating: 4.2 Watts, Power rating with convection cooling (W) , 4.2V in 0.1V increments, Approvals: ETL; CB 60335; | |||||||||||||||||||||||
Information | |||||||||||||||||||||||
Guidelines and cautions, Safety Notes, and Safety Precautions published on GlobTek’s website | |||||||||||||||||||||||
Model Number | GT-91128LIXCEL | ||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | Contact GlobTek for more information | ||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | Contact GlobTek for more information | ||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000MmNnVEAV | ||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000MmNnVEAV | ||||||||||||||||||||||
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf | ||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/r2/eM2co8 | ||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 | ||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||
Type | Wall Plug-in | ||||||||||||||||||||||
Technology | Li-Ion Battery Charger | ||||||||||||||||||||||
Chemistry | |||||||||||||||||||||||
Cell Rated Capacity (mAh) | |||||||||||||||||||||||
Cell Nominal Voltage | |||||||||||||||||||||||
Cell Geometry | |||||||||||||||||||||||
Cell Length | |||||||||||||||||||||||
Cell Width | |||||||||||||||||||||||
Cell Height | |||||||||||||||||||||||
Cell Diameter | |||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||
Specifications | |||||||||||||||||||||||
A) ELECTRICAL SPECIFICATIONS per each channel: Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz Input Current: < 2A RMS Max 01. Charging Voltage: 1 cell: 4.2Vdc, +/-1% Maximum; 2 cell: 8.4Vdc, +/-1% Maximum; 3 cell: 12.6Vdc, +/-1% Maximum 02. Pre-Charge Current: 10% of bulk charge current 03. Bulk Charge Current: ±10% 04. Pre-Charge to Bulk Charge Battery 05. Transition Voltage: 1 cell: 2.86Vdc to 3.15Vdc, 2 cell: 5.72Vdc to 6.30Vdc; 3 cell: 8.58Vdc to 9.45Vdc Charger will be in pre-charge mode when the battery voltage is below the transition voltage. 06. Battery Charging Ambient Temperature: 0°C to 35°C 07. Charge Termination Current: 10% of bulk charge current 08. Back-Up Charge Termination: Timer set 2 to 3 hours after the expected full charge time 09. Charger will terminate charging when timer expired 10. Battery Protection 11. LED Charge Status Indicator a. Pre-Charge: Solid Red b. Bulk Charge: Solid Red c. Charge Complete: Solid Green d. No battery or Fault: Green and Red LED off B) PROTECTION* 01. Over Voltage Protection: 1 cell: 4.6Vdc - 5.0Vdc, 2 cell: 9.2Vdc - 10.0Vdc; 3 cell: 9.2Vdc - 10.0Vdc Charger will terminate charging when over voltage occurs 02. Short Circuit Protection: Charger will not commence charging when BAT+ and BAT- are shorted 03. Reverse Battery Protection: Battery should be mechanically protected from being installed reversed 04. Defective Battery Protection: If battery voltage will not rise above the pre-charge to bulk charge transition voltage (2.86Vdc to 3.15Vdc) within 30 minutes from the time pre-charging begins, the battery is considered defective and the charger will terminate charging. *When fault condition occurs, the battery has to be removed from the charger and reinstalled after at least 3 seconds to reset the protection. Charging will commence after battery reinstallation only when the fault is cleared. C) SAFETY 1. Dielectric Withstand Voltage: 4242 Vdc from primary to secondary 2. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured 3. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition) D) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 35°C ambient temperature 03. Humidity: 0% to 90% relative humidity 04. Storage Temperature: -10°C to 70°C 05. Cooling: Convection E) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Size: 60*65*26 +/-1.0 mm 03. Markings: Label and/or Pad Printed and/or Molded in the case | |||||||||||||||||||||||
Derating Curve | N/A | ||||||||||||||||||||||
Qty (ea.)/Carton | 60 | ||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 142*60*62 | ||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||
Master Carton Size (mm) | 442 x 330 x 275 | ||||||||||||||||||||||
Gross Weight (kg) | 15.2 | ||||||||||||||||||||||
Label Width (mm) | 45.0 | ||||||||||||||||||||||
Label Height (mm) | 50.0 | ||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||
Description | NEMA 1-15P, North America Blades, Class II 2 ConductorsAll NEMA 1 devices are two-wire non-grounding devices (hot-neutral) rated for 125 V maximum. NEMA 1-15P plugs have two parallel flat blades, 0.25 inches (6.35 mm) wide, 0.06 inches (1.524 mm) thick, 0.625-0.718 inches (15.875–18.256 mm) long, and spaced 0.5 inches (12.7 mm) apart. | ||||||||||||||||||||||
Output Configuration | |||||||||||||||||||||||
Common output connector options: Click to add to your request.
Comprehensive list of GlobTek output cordset options Contact GlobTek for your specific requirements or custom solutions. | |||||||||||||||||||||||
Approvals | |||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | |||||||||||||||||||||||
| |||||||||||||||||||||||
Guidelines and cautions, Safety Notes, and Safety Precautions published on GlobTek’s websitehttp://en.globtek.com/safety-cautions.php The purchaser of GlobTek battery pack products (Customer) agrees that they are a "Sophisticated user" who understands battery technology and that it is their sole responsibility to determine suitability of the product described for their application and to take precautions for protection against any hazards attendant to the handling and use of the product. GlobTek products are only designed for professional use and integration by companies into their products and may not be used by consumers directly. GlobTek provides batteries and battery packs as a component of an end system. The acceptance of GlobTek specifications, the information on this page and use of the product(s) described in this or other GlobTek documents indicate that the product was qualified for use (tested and/or sample waiver signed), and the acceptance and binding of the customer to GlobTek terms and conditions, which supersede all other agreements, terms and conditions http://www.globtek.com/about/terms-and-conditions Lithium Ion batteries are inherently dangerous. Continuous usage or charging without allowing the battery to discharge is a hazard. FIRE HAZARD: This like all Li-Ion battery packs must be regularly discharged and charged. it is not recommended to be kept on permanent fullcharge and in a full state of charge. |