ICT / ITE / Medical Power Supply/Class 2/Household Power Supply

GTM96600-60VV.V-T2 Image
Model ImageGTM96600-60VV.V-T2, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply,  60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka \
Information
Model NumberGTM96600-60VV.V-T2
DescriptionGTM96600-60VV.V-T2, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8"), Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-54V in 0.1V increments, Approvals: Korea (41V-54V Only); CB 60335; Fuse 60335; ETL; EAC; cETLus 60601-1; CB 62368; Taiwan BSMI; India BIS; UKCA; UL 1310; cETLus 62368-1; CB 61158; FCC; IP41; Morocco; Korea (9-15V Only); PSE; PSE; PSE; China RoHS; Level VI; RoHS; Ukraine; VCCI; WEEE; ETL; CE; CB 60950; ETL 60950; S-Mark 60950; Double Insulation; RCM; CB 60601-1; S-Mark IEC/EN 60601-1; EAC; CCC; LPS 60950; South Africa; GTM96600-60VV.V-T2, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8"), Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-54V in 0.1V increments, Approvals: Korea (41V-54V Only); CB 60335; Fuse 60335; ETL; EAC; cETLus 60601-1; CB 62368; Taiwan BSMI; India BIS; UKCA; UL 1310; cETLus 62368-1; CB 61158; FCC; IP41; Morocco; Korea (9-15V Only); PSE; PSE; PSE; China RoHS; Level VI; RoHS; Ukraine; VCCI; WEEE; ETL; CE; CB 60950; ETL 60950; S-Mark 60950; Double Insulation; RCM; CB 60601-1; S-Mark IEC/EN 60601-1; EAC; CCC; LPS 60950; South Africa;
Agency Documentshttp://www.globtek.info/certs/GTM96600-TZ/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000FjZOaEAN
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000FjZOaEAN
CE EC-Declaration for Householdhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000FjZOaEAN
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000FjZOaEAN
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000FjZOaEAN
UKCA-Declaration for Householdhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000FjZOaEAN
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000FjZOaEAN
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000FjZOaEAN
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External / desktop/externe
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / adaptateur pour alim à découpage régulée
CategoryICT / ITE / Medical Power Supply/Class 2/Household Power Supply / ICT / ITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)100-240V~, 50-60Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)60
Output Voltage Range (V)5-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionIP41
Size (mm)117.5*53.5*34.2
EnclosureUser-added image
3D File Downloadhttps://www.globtek.com/dl/GTM96600-T2.igs
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM96600-2305-T2*54.522.5
GTM96600-3005-T2*5630
GTM96600-4005-T2*5840
GTM96600-6012-T2*12560
GTM96600-6015-1.2-T2*13.84.3459.89
GTM96600-6015-T2*15460
GTM96600-6018-T2*183.33359.99
GTM96600-6019-T2*193.1559.85
GTM96600-4520-T2*202.2545
GTM96600-6024-T2*242.560
GTM96600-6027-T2*272.2259.94
GTM96600-6048-T2*481.2560
GTM96600-6054-T2*541.1159.94
GTM96600-60VV.V-T2-XXXXCUSTOMCUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       85% rated load current for 85-264VAC
     100% rated load current for 110-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
No Load Input Power:<75mW @ 230VAC (EU CoC Tier 2 compliant) for ≤ 49W rating
<150mW @ 230VAC (EU CoC Tier 2 compliant) for > 49W rating
Inrush Current:30A/60A max. (cold start @ 115V/230VAC)
Efficiency:DoE Level VI and EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second max. @ 115VAC and full load
Output Regulation:± 5% (measured at output connector)
Line Regulation:± 0.5% typ. (measured at output connector)
Ripple:1% or 100mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Transient Response:5% max. deviation, 1ms typ. recovery time (with 40% to 70% load step)
Hold-up Time:8ms typ. (nominal input voltage and full load)
Power Indicator:Green LED

Protections

Input Protection:MOV transient suppressor, input line fusing
Over-Current Protection:110 - 160% of rated output current, auto-restart, current limit range determined by normal output power rating, not de-rated power rating
Short-Circuit Protection:Auto-restart
Over-Voltage Protection:110 - 130%, latched off, cycle AC to reset
Over-Temperature Protection:On-chip temperature sensor (integrated in primary-side switching controller), shut down at Tj = ~140°C, latched off, cycle AC to reset

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-20°C to 40°C (full load)
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Cooling:Convection
RoHS:Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:Regarding operating temperature
a. See below de-rating table for output power capability at alternate temperature
b. Extended low-end temperature range available as a custom option

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:Class I: 20µA max.
Class II: 85µA max.
Class II F2: 20µA max.
Earth Leakage CurrentClass I: 300µA max.
Class II: N/A
Means of Protection:2 x MOPP
Output Isolation Options:Class I: C6 or C14 inlet (output negative tied to Earth contact)
Class II: C8 or C18 inlet
Class II FE: C6 or C14 inlet (output isolated from Earth contact)
Review isolation options by reading our white paper PSU Isolation and Identity.
Earth Continuity Test:< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:See listing at end of this datasheet for specific standards

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 20KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz,  3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
AC Input Mechanical Options:Desktop: C6, C7, C14, or C18 inlet
Hybrid: Desktop inlet or changeable blades for wall-plug-in style, Class I or Class II input
Markings:Label and/or pad printed and/or laser-etched into case

Special Options

  1. Removal of LED (cost reduction or aesthetic purpose)
  2. Custom cordsets, various cordage types, and connector types
  3. Custom markings
  4. Short term output surge capability for motors or other high peak current loads. (Available up to 120W for 1 second at nameplate voltage range. Higher levels possible for limited input voltage range, or larger allowed voltage dip.)
  5. Reduced leakage current
  6. Tightened output voltage tolerance
  7. Reduced output ripple level
  8. Reduced output power rating
  9. High reliability PCB laminate with plated through-holes for IPC610 Class 2 compliance
  10. Low temperature option, down to -40°C
  11. Special housing and cordset colors
  12.  "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
  13. Improved ingress protection (IP) rating

Output Connectors

 

 

Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)427 x 405 x 158
Gross Weight (kg)15.6
Label Width (mm)35.0
Label Height (mm)70.0
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8")
User-added image
Mates with IEC 60320/C7 Plug

Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Please contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

Standard International IEC 320/C7 Cordsets 
Part NumberTypeStandardConnectorLength (mm)Length (feet)
2094112M703(R)Argentina (Type I)IRAM 2063IEC 320/C720007
5014112M703A(R)Australian (Type I)AS 3112IEC 320/C720007
207B4111M8703(R)Brazil (Type N)NBR14136IEC 320/C718006
4533501M8703(R)China (Type A)GB 2099.1IEC 320/C718306
2074112M703A(R)European (Type C)CEE 7/16IEC 320/C720007
2084111M8703B(R)India (Type D)IS 1293IEC 320/C718006
451J3401M8703(R)Japan (Type A)JIS 8303IEC 320/C718306
2044112M703A(R)Korea (Type C)KS C8305IEC 320/C720007
4511116F703A(R)North America (Type A)NEMA 1-15PIEC 320/C718306
2084111M8703(R)South Africa (Type M)BS 546IEC320/C718306
4033401M8703A(R)Taiwan (Type A)CNS690IEC 320/C718306
6104112M703A(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C720007
451G1116F703A(R)Gulf States (Kuwait, Bahrain, Oman, Qatar, Saudi Arabia, Yemen and the United Arab Emirates (UAE)(Type A)Nema 1-15PIEC320/C718306
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added imageBook 60335 up to 36 Volts
User-added imageTaiwan BSMI GTM96600-R2 T2 R32282 GTM96600-6048-R2; http://www.bsmi.gov.tw/wSite/ct?xItem=4072&ctNode=816&mp=2

No Logo Applicable

CB for IEC 60335-1:2010+A1

No Logo Applicable

IEC 60601-1:2005+A1 IEC 60601-1-11:2015

No Logo Applicable

CB for IEC 60950-1:2005+A1+A2

No Logo Applicable

IEC 61558-1:2005+A1, IEC 61558-2-16:2009+A1

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added image
仅适用于海拔5000米以下地区使
 
CCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
User-added image  Test standard: EN 55032:2012+AC:2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image
User-added image  Certification # TC RU C-US.AR46.B.79113 Custom Union of Russia, Belarus and Kazakhstan
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageMedical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance [AAMI ES60601-1:2005 +A1]
User-added imageInformation Technology Equipment Safety Part 1: General Requirements >Valid without technical revision:01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014
User-added imageClass 2 Power Units [UL 1310:2011 Ed.6 +R:12Dec2014] Power Supplies With Extra-Low Voltage Class 2 Outputs [CSA C22.2 No.223:2015 Ed.3]
User-added image
Class 2 Power Unit
Class 2 Power Units [UL 1310:2011 Ed.6 +R:12Dec2014] Power Supplies With Extra-Low Voltage Class 2 Outputs [CSA C22.2 No.223:2015 Ed.3]
UL FCC MarkFCC Mark
User-added imageBureau Of Indian Standards for GTM96600-4005-R2, GTM96600-4005-T2, GTM96600-6012-T2, GTM96600-6012-R2, GTM96600-6015-T2, GTM96600-6015-R2, GTM96600-6024-T2, GTM96600-6024-R2, GTM96600-6048-R2,,GTM96600-6026-P2
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP41Ingress Protection: ?IP41 to IEC60529:2001 Protection against granular foreign bodies - Protected against vertically falling drops of water
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageKorea HU10499-19039A (for GTM96600-6x48-T2,R2(41V-54V)
User-added imageKorea HU10499-20044A (for GTM96600-6x12-T2(A),R2 9-15V)
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source 60950
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageRCM certificate ; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
S-Mark Certificate EN 60601-1:2006+A1+A12, EN 60601-1-11:2015
User-added image
 
S-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
 No LogoSouth Africa approval to SANS IEC 60950
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageUL1310 Warning Label Up To 36 Volts with plugs
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
Qu'est-ce qu'un adaptateur secteur de qualité médicale IEC 60601-1?
Un adaptateur secteur de qualité médicale IEC 60601-1-2 convertit la tension du secteur en une tension inférieure, généralement continue, qui est utilisée pour faire fonctionner et utiliser un équipement médical. Les adaptateurs secteurs de qualité médicale IEC 60601-1-2 sont généralement logés dans un boîtier en plastique et sont disponibles avec des options d'entrée à 2 et 3 broches. Les alimentations électriques sont également disponibles sous forme de châssis ouvert pour une utilisation à l'intérieur des équipements médicaux. Ces convertisseurs CA / CC sont conçus conformément aux normes médicales internationales et assurent le respect de certains de leurs aspects qui diffèrent des alimentations électriques génériques pour les équipements des technologies de l'information et de la communication.

Pourquoi mon bloc d'alimentation de qualité médicale IEC 60601-1 est-il certifié selon IEC 60601-1 3ème édition alors que la dernière norme est IEC 60601-1 4ème édition?
La IEC 60601-1 comprend différentes sections dans les
spécifications de sécurité et EMI / CEM. La dernière révision de la partie sécurité de la IEC 60601-1 est la 3ème édition, tandis que pour les EMI / CEM, la dernière révision est 60601-1-2, 4ème éd. Quelle est la différence entre une alimentation électrique de qualité médicale IEC 60950-1 et IEC 60601-1? Les blocs d'alimentation IEC 60950-1 et IEC 60601-1-2 sont tous deux des convertisseurs CA-CC et peuvent être internes ou externes, mais sont conçus selon des spécifications différentes pour correspondre aux spécifications du système final. Bien que les comportements de performance de base soient similaires, tels que les tensions d'entrée et de sortie et les configurations mécaniques, il existe également de nombreuses différences. Certaines des principales différences sont que les adaptateurs CA / CC médicaux de qualité médicale IEC 60601 sont capables de résister à une tension de tenue diélectrique plus élevée et doivent avoir un courant de fuite inférieur.

Il existe de nombreuses autres différences et considérations à prendre en compte en fonction de l'application finale. Quels MOOP et MOPP?
Les dispositifs médicaux doivent intégrer un ou plusieurs moyens de protection (MOP) pour isoler les patients et les opérateurs des risques d'électrocution. Un moyen de protection (MOP) peut être une isolation de sécurité, une terre de protection, une ligne de fuite définie ou un entrefer ou une autre impédance de protection. Ceux-ci peuvent être utilisés dans diverses combinaisons. La IEC 60601-1 3ème édition fait la distinction entre le risque pour les patients et le risque pour les opérateurs. Un MOP peut donc être classé comme moyen de protection du patient (MOPP) ou moyen de protection de l'opérateur (MOOP). La principale différence entre un MOOP et un MOPP réside principalement dans la distance de fuite autorisée. Les deux exigences sont satisfaites en utilisant l'isolation de base. Pour obtenir la qualification 2 x MOPP, le test d'isolement est particulièrement exigeant à 4000 Vca et la ligne de fuite de 8 mm est le double de celle requise pour un MOPP.

Qu'est-ce qu'un adaptateur secteur d'alimentation nominale IEC 60601-1-2 de qualité médicale classée BF et CF et quelle est la différence?

Les alimentations de qualité médicale et les adaptateurs CA / CC sont classés dans l'un des trois types de pièces appliquées: type corps (B), type flottant (BF) et type flottant cardiaque (CF). Ces pièces appliquées nécessitent des attributs spécifiques tels que la tension d'isolement, la ligne de fuite et le courant de fuite. Flottant fait référence à une alimentation électrique non mise à la terre, Classe II, qui n'est pas référencée à une autre sortie et est entièrement isolée. Le type B fait référence aux dispositifs qui fonctionnent à proximité du patient, comme décrit dans la IEC 60601-1 comme six pieds autour de la chaise ou du lit d'un patient et ne touchent pas le patient électroniquement et sont mis à la terre. Ces dispositifs comprennent l'éclairage de la salle d'opération, les chariots et les lits d'hôpitaux, les distributeurs automatisés de médicaments et de fournitures et l'équipement de diagnostic comme les appareils à rayons X. Les appareils de type BF délivrent des signaux d'énergie électrique vers ou depuis le patient, tels que des appareils électrochirurgicaux, des endoscopes et des moniteurs de signaux vitaux électriques tels que des thermomètres. Les appareils de type CF sont similaires aux BF, sauf qu'ils alimentent les appareils connectés au cœur, tels qu'un défibrillateur, un stimulateur cardiaque externe ou des électrodes ECG intracardiaques et le type CF nécessite un degré de protection plus élevé contre les chocs électriques que les types BF.

Qu'est-ce qu'un adaptateur CA-CC de type "Desktop" ou "Bureau" ?
Les adaptateurs CA-CC externes de bureau sont également appelés adaptateurs CA ou convertisseurs AC-DC et sont un type d'alimentation externe. Certains appareils électriques nécessitent une alimentation mais ne disposent pas des composants internes nécessaires pour obtenir la tension et l'alimentation requises à partir du secteur. C'est là qu'un adaptateur secteur est utilisé pour convertir le courant alternatif en tension continue

Qu'est-ce qu'une alimentation IEC 62368-1: 2018?
La IEC 62368-1: 2018 s'applique à la sécurité des équipements électriques et électroniques dans le domaine de l'audio, de la vidéo, des technologies de l'information et de la communication et des machines professionnelles et de bureau avec une tension nominale ne dépassant pas 600 V. Il s'agit d'une norme de sécurité des produits qui classifie les sources d'énergie, prescrit des garanties contre ces sources d'énergie et fournit des orientations sur l'application et les exigences de ces garanties. Les mesures de protection prescrites visent à réduire la probabilité de douleur, de blessure et, en cas d'incendie, de dommages matériels. Un convertisseur ou un bloc d'alimentation AC / DC classé IEC 62368-1 est un bloc d'alimentation qui a été testé et certifié conforme à ladite norme.

Les blocs d'alimentation IEC 62368-1 vont-ils remplacé les blocs d'alimentation IEC 60950-1?
Le 20 décembre 2020, les normes de sécurité qui se sont historiquement appliquées aux équipements informatiques et audio-vidéo, IEC 60065 et IEC 60950-1, vont passées à la IEC 62368-1. En Amérique du Nord, les certifications ETL et UL 60950-1 resteront valides et pourront être utilisées jusqu'à nouvel ordre.

Quelle est la différence entre une alimentation IEC 62368-1 et une alimentation IEC 60950-1?
Bien que la structure et le contenu des normes soient très différents en général, la plupart des produits qui étaient auparavant conformes à la norme IEC 60950-1 sont conformes à la dernière norme IEC 62368-1 avec peu ou pas de modification.

Mon bloc d'alimentation IEC 60950-1 restera-t-il disponible?
GlobTek continuera à fabriquer et à fournir des alimentations électriques IEC 60950-1 indéfiniment jusqu'à nouvel ordre.

Qu'est-ce que l'efficacité de niveau VI?
Les chiffres I à VI sont un protocole international de marquage d'efficacité qui permet aux fabricants de désigner les performances d'efficacité d'un produit. Ces performances sont basées sur la mesure de l'efficacité énergétique de fonctionnement et de la consommation électrique à vide des alimentations externes ou des adaptateurs CA - CC testés à différents niveaux de charge.
La consommation électrique à vide fait référence à la quantité d'énergie consommée par une alimentation externe même lorsque l'appareil alimenté est éteint ou déconnecté.

L'efficacité de niveau VI est-elle requise?
L'efficacité de niveau VI est obligatoire dans certains pays et régions pour certains produits ou certaines applications.

Qu'est-ce que la directive éco-conception 2009/125 / CE?
La directive sur l'éco-conception a promulgué en Europe les dernières exigences en matière d'efficacité et de conservation énergétiques pour les adaptateurs CA - CC et les alimentations externes.

Comment fonctionne un adaptateur AC-DC ?

L'adaptateur CA / CC ou alimentation externe se compose d'une alimentation qui est enfermée dans un boîtier similaire à une prise secteur, d'où le terme de "plug type", "wall plug in", "plug-in" ou "plugtop power adapter". L'alimentation est branchée sur la prise secteur et la tension alternative est ensuite convertie par l'alimentation en une tension continue qui est délivrée à l'appareil via le câble de sortie.


Demande d'info

Model

GT-46600-WWVV-X.X-T2
60 W, DoE Level VI & CoC Tier 2 Efficiency, Two Prong (C8) Inlet, Desktop Adapter, Ac-Dc Power Supply

DOE EPS 2.0 Level VI Power Supply / Charger / AC Adapter, 60W Desktop/Tabletop, Available with 5-24VDC output Certified to 60950 ITE Standards

GTD93035L6013.2-F

Ruggedized DC/DC converter, 9-60VDC Input and 60W/13.2VDC output. Alternate output voltages available. IEC 60068 Vibration, Shock, Bump, and Salt Mist tested

GT-46600-WWVV-X.X-T3
60 W, DoE Level VI & CoC Tier 2 Efficiency, Three Prong (C14) Inlet, Desktop Adapter, Ac-Dc Power Supply

Level VI Efficiency (EL6)[DOE EPS 2.0] Desktop Power Supply AC Adapter, 60w, output 12-24 VDC

GTM96600-60VV.V-T2A

Class II Medical and ITE power supply with IEC60320/C18 input connector provides 60W of output power in a small package

GT-96600-7056-T3-AP

Level VI, DOE EPS 2.0/ErP2 compliant 70W Power over Ethernet (POE) Injector/ PoE HPOE+ PSE (Power Sourcing Equipment), Gigabit, Four Pair, Class I