World map Français

ICT / ITE / Medical Power Supply

GTM962252PWWWVVX-XF Image
Model Image GTM962252PWWWVVX-XF, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10CFM, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 225 Watts, Power rating with convection cooling (W) 140, 12-54V in 0.1V increments, Approvals: UKCA; CB 60601-1; cETLus 62368-1; CB 60950; CB 62368; China RoHS; EAC; Level VI; RoHS; Ukraine; VCCI; WEEE; Morocco; ETL 62368; ETL; CE;
Information
Model NumberGTM962252PWWWVVX-XF
DescriptionGTM962252PWWWVVX-XF, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10CFM, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 225 Watts, Power rating with convection cooling (W) 140, 12-54V in 0.1V increments, Approvals: UKCA; CB 60601-1; cETLus 62368-1; CB 60950; CB 62368; China RoHS; EAC; Level VI; RoHS; Ukraine; VCCI; WEEE; Morocco; ETL 62368; ETL; CE;
Agency Documentshttp://www.globtek.info/certs/GTM96225xP%20/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000M4jYYEAZ
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000M4jYYEAZ
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000M4jYYEAZ
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000M4jYYEAZ
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O3a00000M4jYYEAZ
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O3a00000M4jYYEAZ
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/Internal / carte/interne
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / adaptateur pour alim à découpage régulée
CategoryICT / ITE / Medical Power Supply / ICT / ITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)3A
Max Output Power Rating (W)225
Output Voltage Range (V)12-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress Protectionna
Size (mm)103.5 (L) x 62.3 (W) x 40.0 (H)
EnclosureUser-added image
User-added image

Customer may need to provide EMI shielding if not in metal chassis

Dimensions for larger alternate 3x5 product are below
3D File Downloadhttps://www.globtek.com/dl/GTM962252PWWWVVX-XF.igs
Rating Table
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GTM962252P22512A-F* 1218.75225
GTM962252P22515A-F* 1515225
GTM962252P22516A-F* 1614.06224.96
GTM962252P22516-F* 1614.06224.96
GTM962252P22518-F* 1812.5225
GTM962252P22518A-F* 1812.5225
GTM962252P22519A-F* 1911.84224.96
GTM962252P22524A-F* 249.37224.88
GTM962252P22530A-F* 307.5225
GTM962252P22536A-F* 366.25225
GTM962252P22536-F* 366.25225
GTM962252P22538A-F* 385.92224.96
GTM962252P22548A-F* 484.69225.12
GTM962252P22554A-F* 544.17225.18
* (Final ordering #/Part No to be defined)
Specifications

Features

  • High power density 2" x 4" format (3" x 5" and 4.22" x 7" formats also available)
  • 2" x 4" version available in L-frame and cage configurations
  • Low conducted & radiated EMI: Class B without external filters, ferrites, or metal planes (all input configurations, into resistive load)
  • Class I, Class II, or Class II with Functional Earth input configurations
  • ITE/ICT and medical (2 x MOPP) certified (suitable for Type-B or Type-BF applications)
  • Auxiliary +12V output

Input

Input Voltage:Specified: 85-264VAC, Nameplate: 100-240VAC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
Input Current:2.75A typ. @ 85VAC, 1.0A typ. @ 230VAC (full load)
No Load Input Power:<150mW
Inrush Current:<75A @ 230VAC (cold start @ 25°C)
Efficiency:90 - 95% typ. (full load)
Power Factor:>0.95 @ 115VAC, >0.90 @ 230VAC, 225W output
>0.90 @ 115VAC, >0.85 @ 230VAC, 100W output

Output

Output Power:225W (10CFM forced air)
140W (natural convection)
Ratings are inclusive of aux output power
Turn-on Delay:< 1 second @ 85VAC
Output Voltage Tolerance:± 2.0% (worst case, set point + load/line regulation)
Load Regulation:± 0.5% (measured at connector)
Line Regulation:± 0.2% (measured at connector)
Ripple:1% pk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)
Transient Response:<5% deviation (with 25% load step), recovery to within 1% in 1ms
Startup Overshoot:<5% (full load)
Hold-up Time:10ms min. (full load)
Aux Output Voltage Regulation:12V ± 2V (10V min. / 14V max.), for 0A ≤ IAux 1.2A

Aux regulation guaranteed when main output power ≥ 15% of 225W rating (~34W).

For main output power < 15%, aux output voltage may drop to < 50% of nominal rating, depending on aux output load. Please check with your system.
For main output = 12V, aux output voltage is same as main output.
Aux Output Current:1.2A (10CFM forced air)
0.8A (natural convection)
Output Indicator:Green LED

Protections

Input Protection:MOV transient suppressor, dual fuses (line + neutral)
Over-Voltage Protection:110-130%. Latched-off, cycle AC to reset
Over-Current Protection:130% typical, auto-recovery
Short Circuit Protection:Non-latched with auto-recovery
Over-Temperature Protection:NTC temperature sensor embedded in transformer, trip between 115 - 120°, latched-off, cycle AC to reset (auto-recovery available as special option)

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-20°C to 50°C (full output power), -25°C to 80°C (derated)
Storage Temperature:-30°C to 85°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m max.
Vibration:Conforms to EN60068-2-6, ISO80601-2, EN1789

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth
Intended Medical Application:Type-B or Type-BF
Touch Current:3-conductor input - NC: <25µA, SFC: <200µA
2-conductor input - NC: <65µA, SFC: <140µA
Earth Leakage Current3-conductor input: <200µA
2-conductor input: N/A
Means of Protection:2 x MOPP
Primary-Secondary Bridging Capacitance:Two IEC60384-14 certified Y1 capacitors in series

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN 55011, EN61000-6-3, EN61000-6-4, CISPR11/CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 20KV air discharge (applied to input or output terminals)
Radiated RF Immunity:EN61000-4-3, 20V/m 80-2700MHz, 80% 1KHz AM, 80% 5Hz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, (6VRMS in ISM/amateur bands), 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 30A/m
Voltage Dip Immunity:EN61000-4-11

Mechanical Formats

GTM962250P:Open-frame
No suffix: 2" x 4" style, 101.6*50.8*30.0mm, 170g
-C suffix: 3" x 5" style, 127.0*64.8*30.0mm, 180g
-D suffix: 4.22" x 7" style, 177.8*107.2*30.0mm, 190g
GTM962251P:L-frame: 103.5*62.3*40.0mm, 230g
GTM962252P:Cage: 103.5*62.3*40.0mm, 250g
Note 1:The open-frame format meets the above EMC specifications as a standalone unit. However, an L-frame or cage version may help to further improve EMI performance, or to help address other system level electrical/mechanical requirements.

Input/Output Connectors

Earth Terminal (J0):Connector on PCB: Kang Yang PCH250 (0.250" x 0.031" Faston)
Recommended mate: TE Connectivity/AMP 2-520184-2
Note: Leave earth terminal disconnected for Class II input
Input Connector (J1):Connector on PCB: JST B2P3-VH
Pin 1: Line, Pin 2: Not used, Pin 3: Neutral
Recommended mate: JST VAR-2 (housing), JST SVA-41T-P1.1 (terminals)
Main Output Connector (J2):Connector on PCB: JST B6P-VH
Pin 1: COM, Pin 2: COM, Pin 3: COM , Pin 4: +VOUT, Pin 5: +VOUT, Pin 6: +VOUT
Recommended mate: JST VHR-6N (housing), JST SVH-21T-P1.1 (terminals)
Aux Output Connector (J3):Connector on PCB: Molex 22-04-1021
Pin 1: COM, Pin 2: +FAN
Recommended mate: Molex 22-01-1022 (housing), Molex 2759 (terminals)

Special Options

  • Custom labels/markings
  • Short term output surge capability
  • Reduced touch current
  • Reduced output ripple
  • Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
  • IEC61000-3-2 Class-C line harmonics for LED lighting applications
  • Non-latching (auto-recover) over-temperature protection
  • Potentiometer to adjust/trim output voltage
  • Custom aux output voltages (5V to 12V), available for main output voltages from 12-24V

Fan Airflow

  • For full 225W output power, the fan should provide at least 10CFM in the direction noted below.

User-added image

Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Cellular Packag
Individual Box/Gift Box Color
Master Carton Size (mm)450 x 461 x 182
Gross Weight (kg)16
Label Width (mm)TBD
Label Height (mm)TBD
Input Configuration
DescriptionUser-added image
Optional Input Wiring Kits are available:
PN/Ordering NoLengthEnd AEnd B
C810070M6VAR2(R)60IEC 60320 C8JST VAR-2
C1410070M6VAR2(R)60IEC 60320 C13JST VAR-2
VAR2210070M7VAR2(R)73JST VAR-2JST VAR-2
Custom lengths, construction, cable types, ferrites, filters, and termination available upon request.
Approvals
LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added imageAttention Mark / Refer to operating manual for operating and service instructions

No Logo Applicable

CB for IEC 60601-1:2005 (Third Edition) + CORR. 1 (2006) + CORR. 2 (2007) + AM1 (2012) or IEC 60601-1 (2012 reprint) (Ed 3.1) up to 48V only

No Logo Applicable

CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added image  CE Certification
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image  Certification # TC RU AR46.B.75423 Custom Union of Russia, Belarus and Kazakhstan
User-added imageMedical Elec. Equip.- Part 1-11: Gen. Req. For Basic Safety & Essential Perf.- Collateral Standard - Req. For Medical Elec. Equip. & Medical Elec. Systems Used In The Home Healthcare Environment [IEC 60601- 1-11:2015 Ed.2]
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
168649312.018.75DC Output Connector JST B6P-VH or equivalent
168648612.018.75DC Output Connector JST B6P-VH or equivalent
185284324.09.375DC Output Connector JST B6P-VH or equivalent
168648754.04.16DC Output Connector JST B6P-VH or equivalent
168649054.04.16DC Output Connector JST B6P-VH or equivalent
Qu'est-ce qu'un adaptateur secteur de qualité médicale IEC 60601-1?
Un adaptateur secteur de qualité médicale IEC 60601-1-2 convertit la tension du secteur en une tension inférieure, généralement continue, qui est utilisée pour faire fonctionner et utiliser un équipement médical. Les adaptateurs secteurs de qualité médicale IEC 60601-1-2 sont généralement logés dans un boîtier en plastique et sont disponibles avec des options d'entrée à 2 et 3 broches. Les alimentations électriques sont également disponibles sous forme de châssis ouvert pour une utilisation à l'intérieur des équipements médicaux. Ces convertisseurs CA / CC sont conçus conformément aux normes médicales internationales et assurent le respect de certains de leurs aspects qui diffèrent des alimentations électriques génériques pour les équipements des technologies de l'information et de la communication.

Pourquoi mon bloc d'alimentation de qualité médicale IEC 60601-1 est-il certifié selon IEC 60601-1 3ème édition alors que la dernière norme est IEC 60601-1 4ème édition?
La IEC 60601-1 comprend différentes sections dans les
spécifications de sécurité et EMI / CEM. La dernière révision de la partie sécurité de la IEC 60601-1 est la 3ème édition, tandis que pour les EMI / CEM, la dernière révision est 60601-1-2, 4ème éd. Quelle est la différence entre une alimentation électrique de qualité médicale IEC 60950-1 et IEC 60601-1? Les blocs d'alimentation IEC 60950-1 et IEC 60601-1-2 sont tous deux des convertisseurs CA-CC et peuvent être internes ou externes, mais sont conçus selon des spécifications différentes pour correspondre aux spécifications du système final. Bien que les comportements de performance de base soient similaires, tels que les tensions d'entrée et de sortie et les configurations mécaniques, il existe également de nombreuses différences. Certaines des principales différences sont que les adaptateurs CA / CC médicaux de qualité médicale IEC 60601 sont capables de résister à une tension de tenue diélectrique plus élevée et doivent avoir un courant de fuite inférieur.

Il existe de nombreuses autres différences et considérations à prendre en compte en fonction de l'application finale. Quels MOOP et MOPP?
Les dispositifs médicaux doivent intégrer un ou plusieurs moyens de protection (MOP) pour isoler les patients et les opérateurs des risques d'électrocution. Un moyen de protection (MOP) peut être une isolation de sécurité, une terre de protection, une ligne de fuite définie ou un entrefer ou une autre impédance de protection. Ceux-ci peuvent être utilisés dans diverses combinaisons. La IEC 60601-1 3ème édition fait la distinction entre le risque pour les patients et le risque pour les opérateurs. Un MOP peut donc être classé comme moyen de protection du patient (MOPP) ou moyen de protection de l'opérateur (MOOP). La principale différence entre un MOOP et un MOPP réside principalement dans la distance de fuite autorisée. Les deux exigences sont satisfaites en utilisant l'isolation de base. Pour obtenir la qualification 2 x MOPP, le test d'isolement est particulièrement exigeant à 4000 Vca et la ligne de fuite de 8 mm est le double de celle requise pour un MOPP.

Qu'est-ce qu'un adaptateur secteur d'alimentation nominale IEC 60601-1-2 de qualité médicale classée BF et CF et quelle est la différence?

Les alimentations de qualité médicale et les adaptateurs CA / CC sont classés dans l'un des trois types de pièces appliquées: type corps (B), type flottant (BF) et type flottant cardiaque (CF). Ces pièces appliquées nécessitent des attributs spécifiques tels que la tension d'isolement, la ligne de fuite et le courant de fuite. Flottant fait référence à une alimentation électrique non mise à la terre, Classe II, qui n'est pas référencée à une autre sortie et est entièrement isolée. Le type B fait référence aux dispositifs qui fonctionnent à proximité du patient, comme décrit dans la IEC 60601-1 comme six pieds autour de la chaise ou du lit d'un patient et ne touchent pas le patient électroniquement et sont mis à la terre. Ces dispositifs comprennent l'éclairage de la salle d'opération, les chariots et les lits d'hôpitaux, les distributeurs automatisés de médicaments et de fournitures et l'équipement de diagnostic comme les appareils à rayons X. Les appareils de type BF délivrent des signaux d'énergie électrique vers ou depuis le patient, tels que des appareils électrochirurgicaux, des endoscopes et des moniteurs de signaux vitaux électriques tels que des thermomètres. Les appareils de type CF sont similaires aux BF, sauf qu'ils alimentent les appareils connectés au cœur, tels qu'un défibrillateur, un stimulateur cardiaque externe ou des électrodes ECG intracardiaques et le type CF nécessite un degré de protection plus élevé contre les chocs électriques que les types BF.

What is an open frame or internal AC-DC Power supply?

Open frame AC-DC power supplies are also known as AC-DC converters and are a type of internal power supply. The open frame AC to DC power supply is built into the inside of a system and used to convert the AC current into DC voltage.

Qu'est-ce qu'une alimentation IEC 62368-1: 2018?
La IEC 62368-1: 2018 s'applique à la sécurité des équipements électriques et électroniques dans le domaine de l'audio, de la vidéo, des technologies de l'information et de la communication et des machines professionnelles et de bureau avec une tension nominale ne dépassant pas 600 V. Il s'agit d'une norme de sécurité des produits qui classifie les sources d'énergie, prescrit des garanties contre ces sources d'énergie et fournit des orientations sur l'application et les exigences de ces garanties. Les mesures de protection prescrites visent à réduire la probabilité de douleur, de blessure et, en cas d'incendie, de dommages matériels. Un convertisseur ou un bloc d'alimentation AC / DC classé IEC 62368-1 est un bloc d'alimentation qui a été testé et certifié conforme à ladite norme.

Les blocs d'alimentation IEC 62368-1 vont-ils remplacé les blocs d'alimentation IEC 60950-1?
Le 20 décembre 2020, les normes de sécurité qui se sont historiquement appliquées aux équipements informatiques et audio-vidéo, IEC 60065 et IEC 60950-1, vont passées à la IEC 62368-1. En Amérique du Nord, les certifications ETL et UL 60950-1 resteront valides et pourront être utilisées jusqu'à nouvel ordre.

Quelle est la différence entre une alimentation IEC 62368-1 et une alimentation IEC 60950-1?
Bien que la structure et le contenu des normes soient très différents en général, la plupart des produits qui étaient auparavant conformes à la norme IEC 60950-1 sont conformes à la dernière norme IEC 62368-1 avec peu ou pas de modification.

Mon bloc d'alimentation IEC 60950-1 restera-t-il disponible?
GlobTek continuera à fabriquer et à fournir des alimentations électriques IEC 60950-1 indéfiniment jusqu'à nouvel ordre.

Qu'est-ce que l'efficacité de niveau VI?
Les chiffres I à VI sont un protocole international de marquage d'efficacité qui permet aux fabricants de désigner les performances d'efficacité d'un produit. Ces performances sont basées sur la mesure de l'efficacité énergétique de fonctionnement et de la consommation électrique à vide des alimentations externes ou des adaptateurs CA - CC testés à différents niveaux de charge.
La consommation électrique à vide fait référence à la quantité d'énergie consommée par une alimentation externe même lorsque l'appareil alimenté est éteint ou déconnecté.

L'efficacité de niveau VI est-elle requise?
L'efficacité de niveau VI est obligatoire dans certains pays et régions pour certains produits ou certaines applications.

Qu'est-ce que la directive éco-conception 2009/125 / CE?
La directive sur l'éco-conception a promulgué en Europe les dernières exigences en matière d'efficacité et de conservation énergétiques pour les adaptateurs CA - CC et les alimentations externes.

Comment fonctionne un adaptateur AC-DC ?

L'adaptateur CA / CC ou alimentation externe se compose d'une alimentation qui est enfermée dans un boîtier similaire à une prise secteur, d'où le terme de "plug type", "wall plug in", "plug-in" ou "plugtop power adapter". L'alimentation est branchée sur la prise secteur et la tension alternative est ensuite convertie par l'alimentation en une tension continue qui est délivrée à l'appareil via le câble de sortie.


Demande d'info

Model

Call
Email
💬
Text
💁
Chat
?
Demande de devis
Pouvons-nous vous aider?