ICT / ITE / Medical Power Supply

GTM962500PWWWVV.V-CX Image
Model ImageGTM962500PWWWVV.V-CX, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, 3 Positon Terminal Block, Output Rating: 250 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: PSE; PSE; PSE; CE; RoHS; China RoHS; Ukraine; WEEE; VCCI; Level VI; EAC; UKCA; CCC (pending); CB 60950 (pending); CB 60601-1 (pending); cETLus UL1310 (pending); ETL (pending); CB 62368 (pending); ETL 62368 (pending); CB 60335 (pending); CB 61347 (pending); Morocco; GTM962500PWWWVV.V-CX, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, 3 Positon Terminal Block, Output Rating: 250 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: PSE; PSE; PSE; CE; RoHS; China RoHS; Ukraine; WEEE; VCCI; Level VI; EAC; UKCA; CCC (pending); CB 60950 (pending); CB 60601-1 (pending); cETLus UL1310 (pending); ETL (pending); CB 62368 (pending); ETL 62368 (pending); CB 60335 (pending); CB 61347 (pending); Morocco;
Information
Model NumberGTM962500PWWWVV.V-CX
DescriptionGTM962500PWWWVV.V-CX, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, 3 Positon Terminal Block, Output Rating: 250 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: PSE; PSE; PSE; CE; RoHS; China RoHS; Ukraine; WEEE; VCCI; Level VI; EAC; UKCA; CCC (pending); CB 60950 (pending); CB 60601-1 (pending); cETLus UL1310 (pending); ETL (pending); CB 62368 (pending); ETL 62368 (pending); CB 60335 (pending); CB 61347 (pending); Morocco; GTM962500PWWWVV.V-CX, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, 3 Positon Terminal Block, Output Rating: 250 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: PSE; PSE; PSE; CE; RoHS; China RoHS; Ukraine; WEEE; VCCI; Level VI; EAC; UKCA; CCC (pending); CB 60950 (pending); CB 60601-1 (pending); cETLus UL1310 (pending); ETL (pending); CB 62368 (pending); ETL 62368 (pending); CB 60335 (pending); CB 61347 (pending); Morocco;
Agency Documentshttp://www.globtek.info/certs/GTM962400P/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000PHWgzEAH
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O0c00000PHWgzEAH
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000PHWgzEAH
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O0c00000PHWgzEAH
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O0c00000PHWgzEAH
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O0c00000PHWgzEAH
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/Internal / carte/interne
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / adaptateur pour alim à découpage régulée
CategoryICT / ITE / Medical Power Supply / ICT / ITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.8 A
Max Output Power Rating (W)250
Output Voltage Range (V)12-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress Protectionna
Size (mm)203*63.5*41
EnclosureUser-added image

 
Rating Table
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM961600P15015.V-CX*1510150
GTM961600P17015.V-CX*1511.333170
GTM962400P18035-CX*355.142179.97
GTM962500P18036-CX*366.94249.84
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
         90-264Vac range @ 100% of rated load current
         85-264 Vac range @ 90% of rated load current
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50/60Hz
03. Power Factor: 0.90 minimum @ 230Vac, 0.97 minimum @ 115Vac
04. Output Regulation: +/- 4% measured at the output connector
05. Line Voltage Regulation: +/- 0.5% typical measured at full load
06. Green Power On Indicator LED
07. Output Ripple (Vp-p): 1% or 200 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uF electrolytic capacitor connected at the end of the output connector at nominal line
08. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 25% to 50% step load
09. Turn-ON Delay: 1 second typical
10. Hold-Up Time: 20 mS minimum
11. Inrush Current: 30A maximum at 115Vac input and 60A maximum at 230Vac input
12. Switching Frequency: Varies from 30KHz to 133KHz
13. Efficiency: > 90%
14. No Load Standby Power: <0.15 W @ 230Vac

B) PROTECTION
01. Input Protection: Input line fusing and 300Vac rated MOV
02. Short Circuit/ Overload: Electronically Protected unit will auto recover upon removal of fault
         Output Current Limit: Current limited to less than 330W / Vnom
         (Vnom = nominal rated output voltage)
03. Over-Temperature: Latching Electronic  Overtemperature protection. Cycle AC OFF to reset.
04. Output Over-Voltage: 110% to 135% of nominal output voltage under full load condition, and less than 60V max. Latching protection, cycle AC OFF to reset.

C) SAFETY
01. Dielectric Withstand Voltage: 4000Vac or 5656Vdc from input to output,
On Class I models, 3000Vac or 4242Vdc from input to earth
02. Earth Leakage Current: Class I models < 300uA, N/A for Class II models
03. Touch Current: Class I models < 20uA, Class II models < 70uA
04. Output Isolation Options:
   a) C8 or C18 Inlet, Class II
   b) C6 or C14 Inlet, Class II FE, Output Isolated from Earth contact
   c) C6 or C14 Inlet,  Class I, Output negative directly attached to Earth contact
05. Earth Continuity Test: < 0.1 Ohm between Earth Pin at AC input and PCB termination point (Class I models only)
06. Means of Protection: 2 x MOPP
07. Primary to Secondary Bridging Capacitance: Two IEC60384-14 certified Y1 type capacitors in series
08. Compliant Standards: See listings at end of this drawing for specifics

D) EMC
EN 60601-1-2, 4th edition
Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4
  Conducted Emissions: Class B, FCC Part 15, Class B
  Radiated Emissions: Class B, FCC Part 15, Class B
Line Frequency Harmonics EN61000-3-2, Class A
Voltage Fluctuations/Flicker EN61000-3-3
 
Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2
  Static Discharge Immunity EN61000-4-2, 10kV Contact Discharge, 18kV air discharge
  Radiated RF Immunity EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM.
  EFT/Burst Immunity EN61000-4-4, 4kV/100kHz.
  Line Surge Immunity EN61000-4-5, 2kV differential, 4kV common-mode
  Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM
  Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m
  Voltage Dip Immunity EN61000-4-11, Criteria

E) OTHER:
01. MTBF: 500,000 Hours @ 50°C ambient temperature, Full Load
02. Operating Temperature:  -10°C to 50°C ambient temperature with full load
    Regarding Operating Temperature, 
    a- See below derating table for output power capability at alternate temperature
    b- Extended low end temperature range down to -40°C available as a custom option
    c- Power rating based upon 10CFM forced air flow
03. Humidity: 0% to 95% relative humidity, non-condensing
04. Storage Temperature: -30°C to 80°C
05. ROHS: Compliant with latest regulations, see approvals section below
06. Operational Altitude: 5000M

F) MECHANICAL
01. Open Frame configuration, standard option
02. L Chassis configuration, alternate option, may be purchase separately
03. Cage Configuration, alternate option, may be purchased separately
04. Alternate input and output connector options (see diagram), terminal block is standard
   a- Terminal Block, screws face up: T762-01-3P Input, T762-01-4P Output, TIANLI
   b- Terminal Block, screws from side: T762-03-3P Input, T762-03-4P Output, TIANLI
   c- Push to Engage Header: A7920W-3P Input, A7920W-40 Output, MOLEX

G) SPECIAL OPTIONS
01. Custom connector types
02. Custom Markings
03. Short term Output Surge Power Capability
04. Reduced Leakage Current version, medical CF leakage current compliance
05. Tightened output voltage tolerance
06. Reduced Output Ripple Level
08. Reduced output power marking/rating
09. High Rel PCB laminate with Plated through Holes for IPC610 Class 2 Compliance
10. LED Lighting Applications, Class C Line Harmonics
11. Constant Current output, for Vnom to 0.75xVnom.  Add “-CC” suffix to model number. Current level is custom selectable.


 
Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Cellular Packag
Individual Box/Gift Box Color
Master Carton Size (mm)450 x 461 x 182
Gross Weight (kg)16
Label Width (mm)TBD
Label Height (mm)TBD
Input Configuration
Description3 Positon Terminal Block
Optional Input Wiring Kits are available:
 
PN/Ordering NoLengthEnd AEnd B
C810070M6MLX5(R)60IEC 60320 C8 (Faston)MOLEX 09-50-3051
C810070M6MLX5HW(R)60IEC 60320 C8 (Hardwired)MOLEX 09-50-3051
C1410070M6MLX5(R)60IEC 60320 C13MOLEX 09-50-3051
MLX5410070M7MLX5(R73MOLEX 09-50-3051MOLEX 09-50-3051
Custom lengths, construction, cable types, ferrites, filters, and termination available upon request.
 
Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)

No Logo Applicable

CB for IEC 60601-1:2005 (Third Edition) + CORR. 1 (2006) + CORR. 2 (2007) + AM1 (2012) or IEC 60601-1 (2012 reprint) (Ed 3.1) up to 48V only (pending)

No Logo Applicable

CB for IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013 (pending)

No Logo Applicable

CB IEC 60950-1:2005 +A1 +A2 (pending)

No Logo Applicable

CB for IEC61347-1:2015 + A1:2017 IEC61347-2-13:2014, A1:2016 (pending)

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition) (pending)
CCC to GB4943.1-2011 GB9254-2008 GB17625.1-2012 (pending)

User-added image  
CE Certification
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2] (pending)
User-added imageConforms to UL Std. 1310 CLASS 2 Power Units Cert. to CSA Std. C22.2 NO. 223 Up to 36 volts (pending)
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageMedical Elec. Equip.- Part 1-11: Gen. Req. For Basic Safety & Essential Perf.- Collateral Standard - Req. For Medical Elec. Equip. & Medical Elec. Systems Used In The Home Healthcare Environment [IEC 60601- 1-11:2015 Ed.2] (pending)
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
Qu'est-ce qu'un adaptateur secteur de qualité médicale IEC 60601-1?
Un adaptateur secteur de qualité médicale IEC 60601-1-2 convertit la tension du secteur en une tension inférieure, généralement continue, qui est utilisée pour faire fonctionner et utiliser un équipement médical. Les adaptateurs secteurs de qualité médicale IEC 60601-1-2 sont généralement logés dans un boîtier en plastique et sont disponibles avec des options d'entrée à 2 et 3 broches. Les alimentations électriques sont également disponibles sous forme de châssis ouvert pour une utilisation à l'intérieur des équipements médicaux. Ces convertisseurs CA / CC sont conçus conformément aux normes médicales internationales et assurent le respect de certains de leurs aspects qui diffèrent des alimentations électriques génériques pour les équipements des technologies de l'information et de la communication.

Pourquoi mon bloc d'alimentation de qualité médicale IEC 60601-1 est-il certifié selon IEC 60601-1 3ème édition alors que la dernière norme est IEC 60601-1 4ème édition?
La IEC 60601-1 comprend différentes sections dans les
spécifications de sécurité et EMI / CEM. La dernière révision de la partie sécurité de la IEC 60601-1 est la 3ème édition, tandis que pour les EMI / CEM, la dernière révision est 60601-1-2, 4ème éd. Quelle est la différence entre une alimentation électrique de qualité médicale IEC 60950-1 et IEC 60601-1? Les blocs d'alimentation IEC 60950-1 et IEC 60601-1-2 sont tous deux des convertisseurs CA-CC et peuvent être internes ou externes, mais sont conçus selon des spécifications différentes pour correspondre aux spécifications du système final. Bien que les comportements de performance de base soient similaires, tels que les tensions d'entrée et de sortie et les configurations mécaniques, il existe également de nombreuses différences. Certaines des principales différences sont que les adaptateurs CA / CC médicaux de qualité médicale IEC 60601 sont capables de résister à une tension de tenue diélectrique plus élevée et doivent avoir un courant de fuite inférieur.

Il existe de nombreuses autres différences et considérations à prendre en compte en fonction de l'application finale. Quels MOOP et MOPP?
Les dispositifs médicaux doivent intégrer un ou plusieurs moyens de protection (MOP) pour isoler les patients et les opérateurs des risques d'électrocution. Un moyen de protection (MOP) peut être une isolation de sécurité, une terre de protection, une ligne de fuite définie ou un entrefer ou une autre impédance de protection. Ceux-ci peuvent être utilisés dans diverses combinaisons. La IEC 60601-1 3ème édition fait la distinction entre le risque pour les patients et le risque pour les opérateurs. Un MOP peut donc être classé comme moyen de protection du patient (MOPP) ou moyen de protection de l'opérateur (MOOP). La principale différence entre un MOOP et un MOPP réside principalement dans la distance de fuite autorisée. Les deux exigences sont satisfaites en utilisant l'isolation de base. Pour obtenir la qualification 2 x MOPP, le test d'isolement est particulièrement exigeant à 4000 Vca et la ligne de fuite de 8 mm est le double de celle requise pour un MOPP.

Qu'est-ce qu'un adaptateur secteur d'alimentation nominale IEC 60601-1-2 de qualité médicale classée BF et CF et quelle est la différence?

Les alimentations de qualité médicale et les adaptateurs CA / CC sont classés dans l'un des trois types de pièces appliquées: type corps (B), type flottant (BF) et type flottant cardiaque (CF). Ces pièces appliquées nécessitent des attributs spécifiques tels que la tension d'isolement, la ligne de fuite et le courant de fuite. Flottant fait référence à une alimentation électrique non mise à la terre, Classe II, qui n'est pas référencée à une autre sortie et est entièrement isolée. Le type B fait référence aux dispositifs qui fonctionnent à proximité du patient, comme décrit dans la IEC 60601-1 comme six pieds autour de la chaise ou du lit d'un patient et ne touchent pas le patient électroniquement et sont mis à la terre. Ces dispositifs comprennent l'éclairage de la salle d'opération, les chariots et les lits d'hôpitaux, les distributeurs automatisés de médicaments et de fournitures et l'équipement de diagnostic comme les appareils à rayons X. Les appareils de type BF délivrent des signaux d'énergie électrique vers ou depuis le patient, tels que des appareils électrochirurgicaux, des endoscopes et des moniteurs de signaux vitaux électriques tels que des thermomètres. Les appareils de type CF sont similaires aux BF, sauf qu'ils alimentent les appareils connectés au cœur, tels qu'un défibrillateur, un stimulateur cardiaque externe ou des électrodes ECG intracardiaques et le type CF nécessite un degré de protection plus élevé contre les chocs électriques que les types BF.

What is an open frame or internal AC-DC Power supply?

Open frame AC-DC power supplies are also known as AC-DC converters and are a type of internal power supply. The open frame AC to DC power supply is built into the inside of a system and used to convert the AC current into DC voltage.

Qu'est-ce que l'efficacité de niveau VI?
Les chiffres I à VI sont un protocole international de marquage d'efficacité qui permet aux fabricants de désigner les performances d'efficacité d'un produit. Ces performances sont basées sur la mesure de l'efficacité énergétique de fonctionnement et de la consommation électrique à vide des alimentations externes ou des adaptateurs CA - CC testés à différents niveaux de charge.
La consommation électrique à vide fait référence à la quantité d'énergie consommée par une alimentation externe même lorsque l'appareil alimenté est éteint ou déconnecté.

L'efficacité de niveau VI est-elle requise?
L'efficacité de niveau VI est obligatoire dans certains pays et régions pour certains produits ou certaines applications.

Qu'est-ce que la directive éco-conception 2009/125 / CE?
La directive sur l'éco-conception a promulgué en Europe les dernières exigences en matière d'efficacité et de conservation énergétiques pour les adaptateurs CA - CC et les alimentations externes.

Comment fonctionne un adaptateur AC-DC ?

L'adaptateur CA / CC ou alimentation externe se compose d'une alimentation qui est enfermée dans un boîtier similaire à une prise secteur, d'où le terme de "plug type", "wall plug in", "plug-in" ou "plugtop power adapter". L'alimentation est branchée sur la prise secteur et la tension alternative est ensuite convertie par l'alimentation en une tension continue qui est délivrée à l'appareil via le câble de sortie.


Demande d'info

Model

Call
Email
💬
Text
💁
Chat
?
Demande de devis
Pouvons-nous vous aider?
Pouvons-nous vous aider?