World map Français

Medical/ICT/ITE/Household use Power Supply

GTM46402-40VV-x.x-Q Image
Model Image GTM46402-40VV-x.x-Q, Medical/ICT/ITE/Household use Power Supply,  60601-1-4th Ed. , Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Blade Options for Q Series Wall Plug-in Power Supplies, Output Rating: 40 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: cETLus 60950-1; cETLus 60601-1-11; UL 1310; PSE; RCM; cETLus 60601-1 3rd; CB 60335; CB 60950; cETLus 60950; CB 60601-1; Fuse 60335; Fuse 60335; cETLus UL1310; UL 1310; SELV; CB 62368; EAC; LPS 60950; 2MOPP; Singapore (24V); CCC; PSE; PSE; UKCA; GEMS (24V); UL 1310; cETLus 62368-1; LPS 62368; ETL 62368; Morocco; EAC; India BIS 48V (pending); CE; Ukraine; VCCI; RoHS; Level VI; FCC; CAN ICES-3; IP52; Double Insulation; WEEE;
Information
Model NumberGTM46402-40VV-x.x-Q
DescriptionGTM46402-40VV-x.x-Q, Medical/ICT/ITE/Household use Power Supply, 60601-1-4th Ed. , Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Blade Options for Q Series Wall Plug-in Power Supplies, Output Rating: 40 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: cETLus 60950-1; cETLus 60601-1-11; UL 1310; PSE; RCM; cETLus 60601-1 3rd; CB 60335; CB 60950; cETLus 60950; CB 60601-1; Fuse 60335; Fuse 60335; cETLus UL1310; UL 1310; SELV; CB 62368; EAC; LPS 60950; 2MOPP; Singapore (24V); CCC; PSE; PSE; UKCA; GEMS (24V); UL 1310; cETLus 62368-1; LPS 62368; ETL 62368; Morocco; EAC; India BIS 48V (pending); CE; Ukraine; VCCI; RoHS; Level VI; FCC; CAN ICES-3; IP52; Double Insulation; WEEE;
Agency Documentshttp://www.globtek.info/certs/GTM46402/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000FivPcEAJ
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000FivPcEAJ
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000FivPcEAJ
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000FivPcEAJ
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000FivPcEAJ
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000FivPcEAJ
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in / enfichable
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / adaptateur pour alim à découpage régulée
CategoryMedical/ICT/ITE/Household use Power Supply / Medical/ICT/ITE/Household use Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.0A
Max Output Power Rating (W)40
Output Voltage Range (V)5-48
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionIndoor Use
Size (mm)43.5 x 74.0 x 35.3
Enclosure    User-added image
 
Rating Table
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GTM46402-3005* 5630
GTM46402-3606-0.05* 5.956.0536
GTM46402-3007.5* 7.5430
GTM46402-3509* 93.8834.92
GTM46402-2512* 122.0824.96
GTM46402-3612* 12336
GTM46402-3713.4* 13.42.7636.98
GTM46402-3713.6* 13.62.7236.99
GTM46402-3713.8* 13.82.6836.98
GTM46402-4015* 152.6639.9
GTM46402-4018* 182.2239.96
GTM46402-3618* 18236
GTM46402-4019* 192.139.9
GTM46402-4024* 241.6639.84
GTM46402-4031* 311.2939.99
GTM46402-4048* 480.83339.98
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
         90-264 Vac range @ 100% of rated load current
         85-264 Vac range @ 85% of rated load current
         110-370 VDC range @ 100% of rated load current
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Regulation: +/- 5% measured at the output connector
04. Line Voltage Regulation: +/- 0.5% typical measured at full load
05. Output Ripple (Vp-p): 1% or 100 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uf electrolytic capacitor connected at the end of the output connector
06. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 40% to 70% step load
07. Turn-ON Delay: 1 second maximum @ full load, nominal line
08. Hold-Up Time: 8 mS typical @ nominal input voltage and full load
09. Inrush Current: 30A/60A maximum cold start @ 115/230Vac input
10. Efficiency: Compliant with Efficiency Level VI and CoC Tier 2 standards
11. No Load Standby Power: <0.075 W @ 230Vac  

B) PROTECTION
01. Input Protection: Input line fusing and 300Vac MOV
02. Short Circuit/ Overload: Electronically Protected unit will auto recover upon removal of fault
        Output Current Limit: 110% to 160% of rated output current
        (upper end of current limit range is determined by normal output power rating,
        not derated output power level)
03. Output Over-Voltage: 110% to 130% of nominal output voltage

C) SAFETY
01. Dielectric Withstand Voltage: 4000Vac or 5656Vdc from input to output
02. Earth Leakage Current: N/A for Class II models
03. Touch Current: < 95uA
04. Means of Protection for Medical Standard: 2 x MOPP
05. Compliant Standards: See listings at end of this drawing for specifics

D) EMC
01. Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4
  Conducted Emissions: Class B, FCC Part 15, Class B
  Radiated Emissions: Class B, FCC Part 15, Class B
02. Line Frequency Harmonics EN61000-3-2, Class A
03. Voltage Fluctuations/Flicker EN61000-3-3
04. Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2
  Static Discharge Immunity EN61000-4-2, 8kV Contact Discharge, 15kV air discharge
  Radiated RF Immunity EN61000-4-3, 3V/m 80-2700MHz,  80% 1KHz AM.
  EFT/Burst Immunity EN61000-4-4, 2kV/100kHz.
  Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode
  Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM
  Power Frequency Magnetic Field Immunity EN61000-4-8, NA
  Voltage Dip Immunity EN61000-4-11, Criteria


E) OTHER:
01. MTBF: 1,000,000 Hours @ 40°C ambient temperature, Full Load
     Projected failure rate expected to be < 0.5% after 5 years, < 3 % after 10 years
02. Operating Temperature: -20°C to 40°C ambient temperature at full load, -40°C to 50°C ambient temperature with derating to 80% load
03. Operating Humidity: 0% to 95% relative humidity, non-condensing
04. Storage Temperature: -40°C to 80°C
05. Operating Altitude: 5000 Meters for IEC 62368-1 and IEC 60335-1. 3000M for IEC 60601-1
06. Ingress Protection: IP40 standard, IP52 available as special option
07. ROHS: Compliant with latest regulations, see approvals section below

F) ENCLOSURE
01. Housing: High impact plastic, 94V0 polycarbonate, non-vented
02. Markings: Label or Laser Printed
03. AC Input mechanical: Replaceable, Class II Wall Plug-in attachments

G) SPECIAL OPTIONS
02. Custom Cordsets, various cordage types, and connector types*
03. Custom Markings
06. Tightened output voltage tolerance
07. Reduced output ripple level
08. Reduced output power rating marking
09. High Rel PCB laminate with Plated through Holes for IPC610 Class 2 Compliance
10. Special Housing Colors and Cordset Colors

 
Derating CurveUser-added image

 
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)440 x 403 x 300
Gross Weight (kg)
Label Width (mm)30
Label Height (mm)21
Input Configuration
DescriptionBlade Options for Q Series Wall Plug-in Power SuppliesData Sheet: http://en.globtek.com/interchangeable-blades.php
Insertion Instructions: http://www.globtek.com/pdf/Instructions-Interchangeable-Blades.pdf
Video: Q-Blade Style Instruction Video


User-added image
 

INPUT CONNECTOR: Q-Socket (below are available blades configurations which are "not included" (unless stated above); can be purchased separately, package with power supply or as a separate "Q-KIT" if specified

01. United States / Canada / Japan  NEMA 1-15P/ IEC PLUG Type A [WORKS IN PLUG B] configuration: NA 2 blades, Class II; US/CA/JP P/N: Q-NA(R)
02. Australian AS 3112 configuration: SAA 2 blade/ IEC TYPE I, Class II; AU P/N: Q-SAA(R)
03. UK BS 1363 configuration: UK 3 blade with dummy Ground/ IEC TYPE G, Class II; GB P/N: Q-UK(R)
04. European CEE 7/16 configuration: Europlug 2 pins/ IEC TYPE C [WORKS IN TYPE E&F], Class II; EU P/N: Q-EU(R)
05. Korean KS C8305 configuration: 2 pins/SIMILAR TO IEC TYPE C, Class II; KR P/N: Q-KR(R)
06. Argentina IRAM 2073 configuration: 2 blades/SIMILAR TO IEC TYPE I; AR P/N: Class II Q-AR(R)
07. China GB 2099 configuration: 2 blades/SIMILAR TO TYPE A, Class II; CN P/N:Q-CN(R)
08. India IS 1293 6A/BS546 configuration: 5A, 3 pins with Dummy Ground, Class II/IEC TYPE D; IN P/N: Q-IN(R)
09. IEC60320/C18 Inlet, Class II; P/N: Q-C18(R)
10. Brazilian NBR6147 configuration: 2 pins, Class II;SIMILAR TO IEC TYPE C BR P/N: Q-BR(R)
11. South Africa SABS164-1, 3 round prongs, Class II + dummy ground, IEC TYPE M P/N: Q-SANS164-1-16A(R)
12. South Africa SABS164-4, 3 round prongs with a notched prong @ 0º, Class II + dummy ground, IEC TYPE M Red, P/N:
Q-SANS164-4L-16A(R)
13. South Africa SABS164-4, 3 round prongs with a notched prong @ -
53º, Class II + dummy ground, Blue, IEC TYPE M, P/N:
Q-SANS164-4C-16A(R)
14. South Africa SABS164-4, 3 round prongs with a notched prong @ +53º, Class II + dummy ground, Black,IEC TYPE M P/N:
Q-SANS164-4R-16A(R)

Kits

01. Q-KIT: 1,2,3,4 above
02. Q-KIT-INTL: 2,3,4 above
03. Q-KIT-6: 1,2,3,4,5,6 above
04. Q-KIT-7: 1,2,3,4,5,6,7 above
05. Q-KIT-8: 1,2,3,4,5,6,7,8 above

Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
2MOPP2 x MOPP (Means of Patient Protection) marked with 2MOPP near model name
User-added imageBook 60335 up to 36 Volts
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition

No Logo Applicable

IEC 60335-1:2010+A1+A2

No Logo Applicable

CB report to IEC 60950-1:2005 (2nd Edition) +A1:2009 + A2:2013

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added image
仅适用于海拔5000米以下地区使
 
CCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
User-added image  CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added image
Class 2 Power Unit
cETLus-Cert 4007497 UL1310 Recognized Component up to 42.4 volts
User-added image
 
Medical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance [AAMI ES60601-1:2005 +A1]Medical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance [CSA C22.2#60601-1:2014
User-added image
 
Information Technology Equipment Safety Part 1: General Requirements (UL 60950-1 Issued: 2007/03/27 Ed: 2 Rev: 2014/10/14) Information Technology Equipment Safety Part 1: General Requirements (CSA C22.2 No. 60950-1 Issued:2007/03/27 Ed: 2 (R2012) Amd. 1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11
Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to UL STD. 1310
 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 1310 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image
User-added image  Certification # TC RU C-US.A?72.B.01639 Custom Union of Russia, Belarus and Kazakhstan (pending)
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
No LogoGreenhouse and Energy Minimum Standards (GEMS) for model GTM46402-4024
User-added imageCompliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.
User-added imageFuse 60335 T2.0A 250VAC Up to 36 volts
CAN ICES-3(B)/NMB-3(B)
Compliance of this PSU with Industry Canada, Class B demonstrated with a standard output load. The ICES law stipulates that system-level testing is required to demonstrate compliance with the ICES-3 emission limits with the actual system load.
User-added imageBureau Of Indian Standards for GTM46402 48V only (pending)
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP52Ingress Protection: ?IP52 to IEC60529:2001 Protected against dust - limited ingress (no harmful deposit) and Protected against direct sprays up to 15 degrees from the vertical (with R-Blades)
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50473430, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD50473430 , to J62368-1(H30) , J55032(H29),J3000(H25)[DC15? 30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50473430, to J62368-1(H30) , J55032(H29),J3000(H25)[DC30? 60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source 60950
LPSLimited Power Source 62368
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageRCM certificate SAA-182146-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
SELVsafety/separated extra-low voltage IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006
User-added imageSingapore 180574-11 for GTM46402-4024
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageUL1310 Warning Label Up To 42.4 Volts with plugs
User-added imageUL1310 Warning Label Up To 42.4 Volts with plugs
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request Distributor Stock (Click to order)
6500945.06.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
16172095.06.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
WR9QA6000LCP-N(R6B)5.06.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 561
WR9QA6000CCP-N(R6B)5.06.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 559
10194325.956.05Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
10195685.956.05Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
WR9QC4000CCP-N(R6B)7.54.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 75
WR9QC4000LCP-N(R6B)7.54.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 129
WR9QD3888LCP-N(R6B)9.03.88Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 109
WR9QD3888CCP-N(R6B)9.03.88Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 68
6730739.03.88LEMO CONNECTOR, P/N: FFA.0S.250.CTAC42 OR EQUIVALENT
156683412.03.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
41639312.03.0Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
170317512.03.0Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
169239712.03.0Stripped 25+/-5mm, Tinned 8+/-2mm with Black Thermal Contracting Sleeve length 10 +3/-1mm or Equal
168648012.03.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
168142712.03.0Female Barrel 5.5*2.1*9.5mm with internal Spring Clip and Locking Notch or Equal
168078412.03.0Female Barrel 5.5*2.1*9.5mm with internal Spring Clip and Locking Notch or Equal
166608912.03.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
166607312.03.0Right Angle Female Barrel 6.5 x 4.4 x 9.5mm ( OD x ID x L) with 1.37mm center pin or Equal
54074312.03.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
144104612.03.0Female Barrel 5.5 * 2.1 * 13.8 mm w/ 6.5mm Thumb Screw S760K or Equal mates with 722A PC722A 722RA
142933912.03.0USB Type-C Connector
175246612.03.0Female Barrel 5.5*2.1*9.5mm with internal Spring Clip and Locking Notch or Equal
54074812.03.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
76591512.03.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
58354412.03.0Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch or Equal
56820512.03.0Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
55195512.03.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
55195412.03.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
61013212.03.0Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch or Equal
55174312.03.0Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
175237612.03.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
175237712.03.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
139352112.03.0Switchcraft S10 with custom overmold.
136130812.02.08Female Barrel 5.5*2.5*9.5mm, Right Angle with internal Spring Clip & Locking Notch or Equal
160129512.03.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
117121012.03.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
95083212.03.0Female Barrel Right Angle, 5.5*2.1*9.5mm with internal Spring Clip and Locking Notch or Equal
91858512.03.0DC Power Plug Assembly Type with twist lock tabs, 2.5mm locking, Kycon P/N KLDX-PA-0202-B-LT NO Equal
171080512.03.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
163959913.42.76Female Barrel, Staight 3.5 * 1.35 * 10 mm, with internal Spring Clip and Locking Notch or Equal
132474813.42.76Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
104963413.42.76Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
122361513.42.8Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
86892713.82.68Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
50945415.02.66Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
82088915.02.7Female Barrel Straight 1.7 x 4.75 x 9.5 mm with internal Spring Clip and Locking Notch or Equal
34589415.02.66Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
168652315.02.663-Pin Female Cable Connector, Blue, Binder P/N 99-9108-00-03, NO EQUIVALENT
148830415.02.66Female Barrel 5.5*2.1*12mm w/ Spring Clip & Locking Notch or Equal
102633615.02.66Right Angle Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
83972615.02.662 Pin FX9
55207815.02.66Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
WR9QG2667CCPNNAR6B15.02.66Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 20
WR9QG2667LCPNNAR6B15.02.66Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 36
54074915.02.66Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
WR9QG2667LCPN(R6B)15.02.66Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 29
176510118.02.0Female Barrel 5.5*2.5*9.5mm, Right Angle No internal Spring Clip nor Locking Notch or Equal
175724718.02.22Female Barrel 5.5*2.5*9.5mm, Right Angle No internal Spring Clip nor Locking Notch or Equal
117453318.02.22Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch or Equal
175724818.02.2Female Barrel 5.5*2.5*9.5mm, Right Angle No internal Spring Clip nor Locking Notch or Equal
WR9QH2100LCPN(R6B)19.02.1Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 41
WR9QH2100CCPN(R6B)19.02.1Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 32
188404019.02.11Female Barrel 6.5 * 4.3 * 9.5 mm Right Angle Plug w/1.4 mm Pin or Equal
185201619.02.1Female Barrel 6.5 * 4.3 * 9.5 mm Right Angle Plug w/1.4 mm Pin or Equal
WR9QH2100CCPNNAR6B19.02.1Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 31
WR9QH2100LCPNNAR6B19.02.1Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 539
175238224.01.66Female Barrel 5.5*2.1*9.5mm with internal Spring Clip and Locking Notch or Equal
56105224.01.67Stripped 25 +/-5mm; Tinned 9 +/- 2mm or Equal
63471424.01.66Stripped 25 +/-1mm; not tinned; with ferrules (non-insulated type)
WR9QI1660CCPN(R6B)24.01.66Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 66
54074624.01.66Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
82393524.01.66Stripped 25 +/-1mm; not tinned; with wire end sleeves red/black (insulated type)
31410324.01.67Stripped 25 +/-5mm; Tinned 9 +/- 2mm or Equal
31430824.01.66Stripped 50+/-5mm, Tinned 6+/-1mm, ribbed or stripe conductor (+)
57737024.01.66Stripped 25 +/-5mm; Tinned 9 +/- 2mm or Equal
175053724.01.662-Pin Female Bulgin connector P/N PX0410/02S/3540 with 2 crimp contacts Bulgin SA3349 NO Equivalent
56105324.01.7Stripped 25 +/-5mm; Tinned 9 +/- 2mm or Equal
57248624.01.66Stripped 50+/-5mm, Tinned 6+/-1mm, ribbed or stripe conductor (+)
56095024.01.67Stripped 25 +/-5mm; Tinned 9 +/- 2mm or Equal
160476624.01.66SWITCHCRAFT S761KS12, Sealed female plug, 5.5 x 2.1, IP68, cable clamp, thread lock, Black, 5A
172966524.01.66Stripped 30±10 mm; Tinned 4±1 mm
172200824.01.67Stripped 50+/-5mm, Tinned 9+/-2mm
168946624.01.66Binder# 79-3410-12-03 series 718: Femal plug, snap-in version or Equal
168648224.01.66Female Barrel 3.8*1.35*11mm, no Locking Notch and Spring Clip or Equal
167230324.01.66Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
150903824.01.66Female Barrel 3.8*1.35*11mm, no Locking Notch and Spring Clip or Equal
143338624.01.66Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
131207524.01.7Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
129511724.01.66Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
177499824.01.66Stripped 50+/-5mm, Tinned 6+/-1mm, ribbed or stripe conductor (+)
106855824.01.7Female Barrel Right Angle, 5.5*2.1*11.5mm with NO internal Spring Clip NOR Locking Notch or Equal
55196524.01.66Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
90658124.01.66Stripped 25 +/-1mm; Tinned 9 +/- 1mm or Equal
110649424.01.664 Pin Locking Kycon or Equal
WR9QI1660LCPN-NAR6B24.01.66Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 145
142371430.00.8Male Stero Plug (3 Pole) 3.5*14mm
WR9QX833CCP-N(R6B)48.00.83Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 53
55196648.00.83Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
52276648.00.83Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
WR9QX833CCPNNAR6B48.00.83Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 53
170553248.00.83Stripped 50 +/-5mm; Tinned 9.5 +/- 2mm or Equal
Qu'est-ce qu'un adaptateur secteur de qualité médicale IEC 60601-1?
Un adaptateur secteur de qualité médicale IEC 60601-1-2 convertit la tension du secteur en une tension inférieure, généralement continue, qui est utilisée pour faire fonctionner et utiliser un équipement médical. Les adaptateurs secteurs de qualité médicale IEC 60601-1-2 sont généralement logés dans un boîtier en plastique et sont disponibles avec des options d'entrée à 2 et 3 broches. Les alimentations électriques sont également disponibles sous forme de châssis ouvert pour une utilisation à l'intérieur des équipements médicaux. Ces convertisseurs CA / CC sont conçus conformément aux normes médicales internationales et assurent le respect de certains de leurs aspects qui diffèrent des alimentations électriques génériques pour les équipements des technologies de l'information et de la communication.

Pourquoi mon bloc d'alimentation de qualité médicale IEC 60601-1 est-il certifié selon IEC 60601-1 3ème édition alors que la dernière norme est IEC 60601-1 4ème édition?
La IEC 60601-1 comprend différentes sections dans les
spécifications de sécurité et EMI / CEM. La dernière révision de la partie sécurité de la IEC 60601-1 est la 3ème édition, tandis que pour les EMI / CEM, la dernière révision est 60601-1-2, 4ème éd. Quelle est la différence entre une alimentation électrique de qualité médicale IEC 60950-1 et IEC 60601-1? Les blocs d'alimentation IEC 60950-1 et IEC 60601-1-2 sont tous deux des convertisseurs CA-CC et peuvent être internes ou externes, mais sont conçus selon des spécifications différentes pour correspondre aux spécifications du système final. Bien que les comportements de performance de base soient similaires, tels que les tensions d'entrée et de sortie et les configurations mécaniques, il existe également de nombreuses différences. Certaines des principales différences sont que les adaptateurs CA / CC médicaux de qualité médicale IEC 60601 sont capables de résister à une tension de tenue diélectrique plus élevée et doivent avoir un courant de fuite inférieur.

Il existe de nombreuses autres différences et considérations à prendre en compte en fonction de l'application finale. Quels MOOP et MOPP?
Les dispositifs médicaux doivent intégrer un ou plusieurs moyens de protection (MOP) pour isoler les patients et les opérateurs des risques d'électrocution. Un moyen de protection (MOP) peut être une isolation de sécurité, une terre de protection, une ligne de fuite définie ou un entrefer ou une autre impédance de protection. Ceux-ci peuvent être utilisés dans diverses combinaisons. La IEC 60601-1 3ème édition fait la distinction entre le risque pour les patients et le risque pour les opérateurs. Un MOP peut donc être classé comme moyen de protection du patient (MOPP) ou moyen de protection de l'opérateur (MOOP). La principale différence entre un MOOP et un MOPP réside principalement dans la distance de fuite autorisée. Les deux exigences sont satisfaites en utilisant l'isolation de base. Pour obtenir la qualification 2 x MOPP, le test d'isolement est particulièrement exigeant à 4000 Vca et la ligne de fuite de 8 mm est le double de celle requise pour un MOPP.

Qu'est-ce qu'un adaptateur secteur d'alimentation nominale IEC 60601-1-2 de qualité médicale classée BF et CF et quelle est la différence?

Les alimentations de qualité médicale et les adaptateurs CA / CC sont classés dans l'un des trois types de pièces appliquées: type corps (B), type flottant (BF) et type flottant cardiaque (CF). Ces pièces appliquées nécessitent des attributs spécifiques tels que la tension d'isolement, la ligne de fuite et le courant de fuite. Flottant fait référence à une alimentation électrique non mise à la terre, Classe II, qui n'est pas référencée à une autre sortie et est entièrement isolée. Le type B fait référence aux dispositifs qui fonctionnent à proximité du patient, comme décrit dans la IEC 60601-1 comme six pieds autour de la chaise ou du lit d'un patient et ne touchent pas le patient électroniquement et sont mis à la terre. Ces dispositifs comprennent l'éclairage de la salle d'opération, les chariots et les lits d'hôpitaux, les distributeurs automatisés de médicaments et de fournitures et l'équipement de diagnostic comme les appareils à rayons X. Les appareils de type BF délivrent des signaux d'énergie électrique vers ou depuis le patient, tels que des appareils électrochirurgicaux, des endoscopes et des moniteurs de signaux vitaux électriques tels que des thermomètres. Les appareils de type CF sont similaires aux BF, sauf qu'ils alimentent les appareils connectés au cœur, tels qu'un défibrillateur, un stimulateur cardiaque externe ou des électrodes ECG intracardiaques et le type CF nécessite un degré de protection plus élevé contre les chocs électriques que les types BF.

Qu'est-ce qu'une alimentation IEC 62368-1: 2018?
La IEC 62368-1: 2018 s'applique à la sécurité des équipements électriques et électroniques dans le domaine de l'audio, de la vidéo, des technologies de l'information et de la communication et des machines professionnelles et de bureau avec une tension nominale ne dépassant pas 600 V. Il s'agit d'une norme de sécurité des produits qui classifie les sources d'énergie, prescrit des garanties contre ces sources d'énergie et fournit des orientations sur l'application et les exigences de ces garanties. Les mesures de protection prescrites visent à réduire la probabilité de douleur, de blessure et, en cas d'incendie, de dommages matériels. Un convertisseur ou un bloc d'alimentation AC / DC classé IEC 62368-1 est un bloc d'alimentation qui a été testé et certifié conforme à ladite norme.

Les blocs d'alimentation IEC 62368-1 vont-ils remplacé les blocs d'alimentation IEC 60950-1?
Le 20 décembre 2020, les normes de sécurité qui se sont historiquement appliquées aux équipements informatiques et audio-vidéo, IEC 60065 et IEC 60950-1, vont passées à la IEC 62368-1. En Amérique du Nord, les certifications ETL et UL 60950-1 resteront valides et pourront être utilisées jusqu'à nouvel ordre.

Quelle est la différence entre une alimentation IEC 62368-1 et une alimentation IEC 60950-1?
Bien que la structure et le contenu des normes soient très différents en général, la plupart des produits qui étaient auparavant conformes à la norme IEC 60950-1 sont conformes à la dernière norme IEC 62368-1 avec peu ou pas de modification.

Mon bloc d'alimentation IEC 60950-1 restera-t-il disponible?
GlobTek continuera à fabriquer et à fournir des alimentations électriques IEC 60950-1 indéfiniment jusqu'à nouvel ordre.

Qu'est-ce que l'efficacité de niveau VI?
Les chiffres I à VI sont un protocole international de marquage d'efficacité qui permet aux fabricants de désigner les performances d'efficacité d'un produit. Ces performances sont basées sur la mesure de l'efficacité énergétique de fonctionnement et de la consommation électrique à vide des alimentations externes ou des adaptateurs CA - CC testés à différents niveaux de charge.
La consommation électrique à vide fait référence à la quantité d'énergie consommée par une alimentation externe même lorsque l'appareil alimenté est éteint ou déconnecté.

L'efficacité de niveau VI est-elle requise?
L'efficacité de niveau VI est obligatoire dans certains pays et régions pour certains produits ou certaines applications.

Qu'est-ce que la directive éco-conception 2009/125 / CE?
La directive sur l'éco-conception a promulgué en Europe les dernières exigences en matière d'efficacité et de conservation énergétiques pour les adaptateurs CA - CC et les alimentations externes.

Qu'est-ce qu'un adaptateur CA-CC enfichable?
Les adaptateurs CA-CC enfichables sont également appelés adaptateurs CA ou convertisseurs CA-CC et constituent un type d'alimentation externe. Certains appareils électriques nécessitent une alimentation mais ne disposent pas des composants internes nécessaires pour obtenir la tension et l'alimentation requises à partir du secteur. C'est là qu'un adaptateur secteur est utilisé pour convertir le courant alternatif en tension continue

Comment fonctionne un adaptateur AC-DC ?

L'adaptateur CA / CC ou alimentation externe se compose d'une alimentation qui est enfermée dans un boîtier similaire à une prise secteur, d'où le terme de "plug type", "wall plug in", "plug-in" ou "plugtop power adapter". L'alimentation est branchée sur la prise secteur et la tension alternative est ensuite convertie par l'alimentation en une tension continue qui est délivrée à l'appareil via le câble de sortie.


Demande d'info

Model

GT-46401-WWVV-x.x-Q

DOE EPS 2.0 Level VI Power Supply / Charger / AC Adapter, 40W Interchangeable Plugs wall plug in with Class II Input, Available with 12-24VDC output Certified to Medical and ITE Standards

Call
Email
💬
Text
💁
Chat
?
Demande de devis
Pouvons-nous vous aider?
Pouvons-nous vous aider?