World map Français

alimentation médicale

GTM41134-WWVV-F Image
Model Image GTM41134-WWVV-F, Medical Power Supply,  60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 09-65-2058 5 Position Header Pin 1: Earth, Pin 2: Removed, PIN 3: Neutral, Pin 4: removed, Pin 5: Line, Output Rating: 6 Watts, Power rating with convection cooling (W) , 3.3-48V in 0.1V increments, Approvals: UKCA; CB 62368; S-Mark 62368; cETLus 62368-1; ETL 62368; LPS 60950; CE; EAC; WEEE; VCCI; China RoHS; RoHS; Ukraine; Book 60601; CB 60601-1 2MOPP; PSE; Level V; RCM;
Information
Model NumberGTM41134-WWVV-F
DescriptionGTM41134-WWVV-F, Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 09-65-2058 5 Position Header Pin 1: Earth, Pin 2: Removed, PIN 3: Neutral, Pin 4: removed, Pin 5: Line, Output Rating: 6 Watts, Power rating with convection cooling (W) , 3.3-48V in 0.1V increments, Approvals: UKCA; CB 62368; S-Mark 62368; cETLus 62368-1; ETL 62368; LPS 60950; CE; EAC; WEEE; VCCI; China RoHS; RoHS; Ukraine; Book 60601; CB 60601-1 2MOPP; PSE; Level V; RCM;
Agency Documentshttp://www.globtek.info/certs/GTM41134/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MEXnlEAH
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MEXnlEAH
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MEXnlEAH
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MEXnlEAH
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000MEXnlEAH
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000MEXnlEAH
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/Internal / carte/interne
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor / adaptateur pour alim à découpage régulée
CategoryMedical Power Supply / alimentation médicale
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)0.6A Max
Max Output Power Rating (W)6
Output Voltage Range (V)3.3-48
EfficiencyN/A
Ingress Protection
Size (mm)84.5*41.5*17.0
EnclosureUser-added image
 
 
Rating Table
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GTM41134-0603-F* 3.31.85.94
GTM41134-0606-1.0-F* 51.26
GTM41134-0606-F* 616
GTM41134-0612-5.0-F* 70.855.95
GTM41134-0612-3.0-F* 90.665.94
GTM41134-0612-F* 120.56
GTM41134-0615-F* 150.46
GTM41134-0618-2.0-F* 160.3756
GTM41134-0618-F* 180.335.94
GTM41134-0624-5.0-F* 190.315.89
GTM41134-0624-4.0-F* 200.36
GTM41134-0624-F* 240.256
GTM41134-0636-2.5-F* 33.50.1796
GTM41134-0636-F* 360.165.76
GTM41134-0648-F* 480.1256
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
02. IInput Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Current: Current limited to rated output current with tolerance of +/-10%
04. Output Regulation: +/- 5% measured at the output connector
05. Line Voltage Regulation: +/- 1% typical measures at full load
06. Output Ripple (Vp-p): 1% or 150 mV whichever is greater measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of output connector at nominal line
07. Turn-On/Turn-Off Overshoot: 5% maximum, 1mS typical recovery time for 25% step load
08. Turn-On Delay: 1 second typical
09. Hold-Up Time: 8mS typical @ nominal input voltage & full load
10. Inrush Current: 30A typical @ 115Vac input ; 60A typical @ 230Vac input
11. Switching Frequency: 65 KHz typical

B) PROTECTION
1. Over-Voltage: Unit will recover upon removal of fault
2. Short Circuit: Electronically Protected, unit will recover upon removal of fault
3. Input Protection: Input line fusing

C) SAFETY
1. Dielectric Withstand Voltage: Input-Output: 5656Vdc, (2 MOPP)
2. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured
3. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)
4. Means of Protection: 2 x MOPP
5. Primary to Secondary Bridging Capacitor: Standard configuration provided without bridging capacitors, Two (2) * Y1 type capacitors in series is available as an option upon customer request. If option employed, it is to be noted in the product deviation section of this specification document.

D) OTHER:
1. MTBF: 200,000 hours @ 25°C ambient temperature
2. Operating Temperature: 0°C to 40°C ambient temperature
3. Humidity: 0% to 95% relative humidity (RFP RFI-33542-1)
4. Storage Temperature: -20°C to 80°C
Normal performance after 2h recovery time at the room temperature without connection to mains (RFP RFI-33542-1)

E) ENCLOSURE
1. Upper Housing: High impact plastic, 94V0 polycarbonate, non-vented
2. Lower Housing: High impact plastic, 94V0 polycarbonate, non-vented
3. Size: 43.5 x 74.0 x 35.3mm +/- 1.0
Derating Curve
Qty (ea.)/Carton120
Individual Box/Gift Box Size (mm)90*45*30
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)455 x 405 x 220
Gross Weight (kg)21.1
Label Width (mm)25.4
Label Height (mm)17.8
Input Configuration
DescriptionMolex 09-65-2058 5 Position Header Pin 1: Earth, Pin 2: Removed, PIN 3: Neutral, Pin 4: removed, Pin 5: LineDocument: http://www.molex.com/pdm_docs/sd/009652058_sd.pdf
Catalog Page: http://www.molex.com/molex/products/datasheet.jsp?part=active/0009652058_PCB_HEADERS.xml
   User-added image
User-added image

Mates With Part(s):
5195 SPOX™ Crimp Housing, 5239 KK® Crimp Housing

Approvals
LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added image60601-1 3rd Operating Instructions
No Logo ApplicableCB report IEC60601-1 2005 A1+C1+C2 2016-2-4 and or EN 60601-1:2006 3.1rd Edition 2xMOPP

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image  Certification # TC RU AR46.B.72092 Custom Union of Russia, Belarus and Kazakhstan for GT(M)41134
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source 60950
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
User-added imageRCM certificate SAA-152514-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm) (update pending)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/)
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
1682065.01.2Molex 4-Pin 2.54mm Pitch Friction Lock Header P/N 22-23-2041 (4 Circuit)
40838112.00.5Molex 4-Pin 2.54mm Pitch Friction Lock Header P/N 22-23-2041 (4 Circuit)
Qu'est-ce qu'un adaptateur secteur de qualité médicale IEC 60601-1?
Un adaptateur secteur de qualité médicale IEC 60601-1-2 convertit la tension du secteur en une tension inférieure, généralement continue, qui est utilisée pour faire fonctionner et utiliser un équipement médical. Les adaptateurs secteurs de qualité médicale IEC 60601-1-2 sont généralement logés dans un boîtier en plastique et sont disponibles avec des options d'entrée à 2 et 3 broches. Les alimentations électriques sont également disponibles sous forme de châssis ouvert pour une utilisation à l'intérieur des équipements médicaux. Ces convertisseurs CA / CC sont conçus conformément aux normes médicales internationales et assurent le respect de certains de leurs aspects qui diffèrent des alimentations électriques génériques pour les équipements des technologies de l'information et de la communication.

Pourquoi mon bloc d'alimentation de qualité médicale IEC 60601-1 est-il certifié selon IEC 60601-1 3ème édition alors que la dernière norme est IEC 60601-1 4ème édition?
La IEC 60601-1 comprend différentes sections dans les
spécifications de sécurité et EMI / CEM. La dernière révision de la partie sécurité de la IEC 60601-1 est la 3ème édition, tandis que pour les EMI / CEM, la dernière révision est 60601-1-2, 4ème éd. Quelle est la différence entre une alimentation électrique de qualité médicale IEC 60950-1 et IEC 60601-1? Les blocs d'alimentation IEC 60950-1 et IEC 60601-1-2 sont tous deux des convertisseurs CA-CC et peuvent être internes ou externes, mais sont conçus selon des spécifications différentes pour correspondre aux spécifications du système final. Bien que les comportements de performance de base soient similaires, tels que les tensions d'entrée et de sortie et les configurations mécaniques, il existe également de nombreuses différences. Certaines des principales différences sont que les adaptateurs CA / CC médicaux de qualité médicale IEC 60601 sont capables de résister à une tension de tenue diélectrique plus élevée et doivent avoir un courant de fuite inférieur.

Il existe de nombreuses autres différences et considérations à prendre en compte en fonction de l'application finale. Quels MOOP et MOPP?
Les dispositifs médicaux doivent intégrer un ou plusieurs moyens de protection (MOP) pour isoler les patients et les opérateurs des risques d'électrocution. Un moyen de protection (MOP) peut être une isolation de sécurité, une terre de protection, une ligne de fuite définie ou un entrefer ou une autre impédance de protection. Ceux-ci peuvent être utilisés dans diverses combinaisons. La IEC 60601-1 3ème édition fait la distinction entre le risque pour les patients et le risque pour les opérateurs. Un MOP peut donc être classé comme moyen de protection du patient (MOPP) ou moyen de protection de l'opérateur (MOOP). La principale différence entre un MOOP et un MOPP réside principalement dans la distance de fuite autorisée. Les deux exigences sont satisfaites en utilisant l'isolation de base. Pour obtenir la qualification 2 x MOPP, le test d'isolement est particulièrement exigeant à 4000 Vca et la ligne de fuite de 8 mm est le double de celle requise pour un MOPP.

Qu'est-ce qu'un adaptateur secteur d'alimentation nominale IEC 60601-1-2 de qualité médicale classée BF et CF et quelle est la différence?

Les alimentations de qualité médicale et les adaptateurs CA / CC sont classés dans l'un des trois types de pièces appliquées: type corps (B), type flottant (BF) et type flottant cardiaque (CF). Ces pièces appliquées nécessitent des attributs spécifiques tels que la tension d'isolement, la ligne de fuite et le courant de fuite. Flottant fait référence à une alimentation électrique non mise à la terre, Classe II, qui n'est pas référencée à une autre sortie et est entièrement isolée. Le type B fait référence aux dispositifs qui fonctionnent à proximité du patient, comme décrit dans la IEC 60601-1 comme six pieds autour de la chaise ou du lit d'un patient et ne touchent pas le patient électroniquement et sont mis à la terre. Ces dispositifs comprennent l'éclairage de la salle d'opération, les chariots et les lits d'hôpitaux, les distributeurs automatisés de médicaments et de fournitures et l'équipement de diagnostic comme les appareils à rayons X. Les appareils de type BF délivrent des signaux d'énergie électrique vers ou depuis le patient, tels que des appareils électrochirurgicaux, des endoscopes et des moniteurs de signaux vitaux électriques tels que des thermomètres. Les appareils de type CF sont similaires aux BF, sauf qu'ils alimentent les appareils connectés au cœur, tels qu'un défibrillateur, un stimulateur cardiaque externe ou des électrodes ECG intracardiaques et le type CF nécessite un degré de protection plus élevé contre les chocs électriques que les types BF.

What is an open frame or internal AC-DC Power supply?

Open frame AC-DC power supplies are also known as AC-DC converters and are a type of internal power supply. The open frame AC to DC power supply is built into the inside of a system and used to convert the AC current into DC voltage.

Qu'est-ce qu'une alimentation IEC 62368-1: 2018?
La IEC 62368-1: 2018 s'applique à la sécurité des équipements électriques et électroniques dans le domaine de l'audio, de la vidéo, des technologies de l'information et de la communication et des machines professionnelles et de bureau avec une tension nominale ne dépassant pas 600 V. Il s'agit d'une norme de sécurité des produits qui classifie les sources d'énergie, prescrit des garanties contre ces sources d'énergie et fournit des orientations sur l'application et les exigences de ces garanties. Les mesures de protection prescrites visent à réduire la probabilité de douleur, de blessure et, en cas d'incendie, de dommages matériels. Un convertisseur ou un bloc d'alimentation AC / DC classé IEC 62368-1 est un bloc d'alimentation qui a été testé et certifié conforme à ladite norme.

Les blocs d'alimentation IEC 62368-1 vont-ils remplacé les blocs d'alimentation IEC 60950-1?
Le 20 décembre 2020, les normes de sécurité qui se sont historiquement appliquées aux équipements informatiques et audio-vidéo, IEC 60065 et IEC 60950-1, vont passées à la IEC 62368-1. En Amérique du Nord, les certifications ETL et UL 60950-1 resteront valides et pourront être utilisées jusqu'à nouvel ordre.

Quelle est la différence entre une alimentation IEC 62368-1 et une alimentation IEC 60950-1?
Bien que la structure et le contenu des normes soient très différents en général, la plupart des produits qui étaient auparavant conformes à la norme IEC 60950-1 sont conformes à la dernière norme IEC 62368-1 avec peu ou pas de modification.

Mon bloc d'alimentation IEC 60950-1 restera-t-il disponible?
GlobTek continuera à fabriquer et à fournir des alimentations électriques IEC 60950-1 indéfiniment jusqu'à nouvel ordre.

Comment fonctionne un adaptateur AC-DC ?

L'adaptateur CA / CC ou alimentation externe se compose d'une alimentation qui est enfermée dans un boîtier similaire à une prise secteur, d'où le terme de "plug type", "wall plug in", "plug-in" ou "plugtop power adapter". L'alimentation est branchée sur la prise secteur et la tension alternative est ensuite convertie par l'alimentation en une tension continue qui est délivrée à l'appareil via le câble de sortie.


Demande d'info

Model

Call
Email
💬
Text
💁
Chat
?
Demande de devis
Pouvons-nous vous aider?
Pouvons-nous vous aider?